Filter Results By:

Products

Applications

Manufacturers

Test Systems

group of interoperable devices whose integration perform a common test purpose.

See Also: Systems, Equipment, System Integrators, System Test, System Integration


Showing results: 4216 - 4230 of 5217 items found.

  • Nuclear EMC Testing Services

    Washington Laboratories LTD.

    The implementation of digital control and monitoring systems in nuclear power plants drives EMC requirements for new and replacement equipment to be used in nuclear plants. For the past 20 years, the Electric Power Research Institute (EPRI) has been developing test methods to demonstrate compliance with EMC requirements. The methods and limits are called out in EPRI TR-102323. The first issue of this report was released in 1994 and the current revision (Revision 4) was released in 2013. The original report and basis included results from electromagnetic surveys at seven nuclear power plants in the United States.

  • FPGA PXI Digital I/O Card

    GX3500 - Terotest Systems Ltd.

    The GX3500 is a user configurable 3U FPGA PXI card which offers 160 digital I/O signals for specific application needs. The card employs the Altera Cyclone III FPGA which can support clock rates up to 150 MHz and features over 55,000 logic elements and 2.34 Mb of memory. The 3U PXI FPGA card GX3500 can also accept an expansion card assembly which can be used to customize the interface to the UUT – eliminating the need for additional external boards which are cumbersome and physically difficult to integrate into a test system.

  • 128 Channel Digital I/O Modular PXI Card

    GX5733 - Terotest Systems Ltd.

    The GX5733 is a 3U modular digital I/O card that offers up to 128 I/O channels. Designed for ATE, data acquisition, or process control systems where a large number of discrete I/O channels are required, the GX5733 offers the highest channel density and flexibility in the industry for a single slot, 3U PXI plug-in board. 96 channels support TTL levels and an additional 32 I/O channels can be customized by installing one of Marvin Test Solutions' GX57xx series I/O modules. Alternatively, the remaining port can be configured to support 32 TTL channels.

  • 1 A DIGITAL MILIOHMMETER

    MO-2Ke - MEGABRAS srl

    The MO-2Ke digital low resistance ohmmeter is a portable, microprocessor-controlled instrument used to accurately measure resistances of contacts, switches, transformer and motor windings, etc., using test currents from 1 mA up to 1 A.It uses the Kelvin-type (4-terminals) measurement principle, thus eliminating errors caused by lead and contact resistances.Resistance readings are shown in the alphanumeric display with up to a 4 digit-resolution. It allows to measure resistances of up to 2 kO, with resolution of 0.01 mO.Measurements accuracy is guaranteed by the state-of-the-art system for signal-amplification, offset-free and with long-term stability.

  • Advanced Test Platform

    980b - Teledyne LeCroy quantumdata

    The Teledyne LeCroy quantumdata 980B platform is a modular based system that can accommodate up to three (3) to four (4) 980 series modules depending the modules configured. The 980B platform and its modules can be controlled either through the PC-based 980 GUI Manager or through the embedded 980 GUI Manager running on the 980B platform itself. The 980B Test Platform’s built-in color touch screen provides a graphical user interface (GUI) to control the instrument and to view incoming video and metadata in the Real Time mode when using the 980 modules with analyzer functions.

  • Booster and In-line Amplifier

    Amonics Ltd.

    Amonics' EDFA range adopts unique design to produce maximum signal gain and saturated output power while maintaining low noise figure, enabling test capabilities in system or component level manufacturing and characterizing processes, as well as facilitating highly demanding R&D applications. The compact turnkey benchtop or 19" rackmount unit incorporates a user-friendly front panel housing with a LCD monitor display, key switch, power control knob and optical connectors. An integrated RS232 computer interface enables easy control, diagnostic functions and data acquisition.

  • MLDD 4-Way Power Dividers

    KRYTAR, Inc.

    KRYTAR MLDD 4-way power dividers lend themselves to emerging wireless ultra-broadband designs and many test and measurement applications. KRYTAR’s power dividers offer the widest frequency coverage in a single package on the market and provides superior performance. Targeting broadband electronic warfare (EW) systems and complex switch-matrix applications, for example, KRYTAR has used its proprietary design to produce a wide assortment of matched-line directional dividers (MLDD) with ultra-high performance over a broadband frequency range. Our 4-way power dividers can also be manufactured to meet military specifications.

  • MLDD 8-Way Power Dividers

    KRYTAR, Inc.

    KRYTAR MLDD 8-way power dividers lend themselves to emerging wireless ultra-broadband designs and many test and measurement applications. KRYTAR’s power dividers offer the widest frequency coverage in a single package on the market and provides superior performance. Targeting broadband electronic warfare (EW) systems and complex switch-matrix applications, for example, KRYTAR has used its proprietary design to produce a wide assortment of matched-line directional dividers (MLDD) with ultra-high performance over a broadband frequency range. Our 8-way power dividers can also be manufactured to meet military specifications.

  • Multi-Zone Gas Monitor

    HGM-MZ - IMR Environmental Equipment, Inc.

    The Multi-Zone Monitor provides continuous detection of refrigerant gas levels in up to 16 separate test zones and can be fitted with an optional two channel 4-20 mA current loop board for connection to remote monitoring equipment. Multi-Zone monitors retain a log of previous readings that can be easily accessed for analysis. Four relay contacts are provided that can be programmed to trigger external alarm devices in the event of a system fault, or if a leak (small), spill (medium) or evacuation (large) level of gas is detected, while audible and visual front panel indicators show alarm and fault conditions.

  • Multifunction Instrument

    COMBI521EV - HT Italia Srl

    COMBI521EV is the new HT instrument to perform verification and control of electric car charging stations (EVSE) safety according to IEC / EN 61851-1 and IEC / EN60364-7-722 standards. Being a combined verification instrument, COMBI521EV also carries out tests on electric systems in compliance with IEC/EN 61557-1 and therefore measurements of continuity of the protection cable, insulation resistance (with calculation of PI and DAR), overall earth resistance, RCDs type B, A and AC tripping time and current, line / fault impedance with calculation of prospective short circuit / fault current, phase sequence and conformity.

  • STANAG3910 Electrica lTest And Simulation Modulefor Standard Ethernet

    ANET3910-EN - AIM GmbH

    STANAG3910 Electrical Test and Simulation module for Standard Ethernet. The ANET embedded Linux operating system gives the unique capability to run the optional PBA.pro Engine right in the box.Another option is the ANET-ADK onboard software development kit where users create run-time applications to execute right in the box. For wireless applications, an ANET compatible USB Wifi dongle is optionally available. The capability to execute Python scripts in the ANET is a standard feature. For applications with multiple ANET devices AIM offers the ADock ANET Docking Station to host up to 4 ANET modules.

  • 128 Channel Digital I/O Modular PXI Card

    GX5733 Series - Marvin Test Solutions, Inc.

    The GX5733 is a 3U modular digital I/O card that offers up to 128 I/O channels. Designed for ATE, data acquisition, or process control systems where a large number of discrete I/O channels are required, the GX5733 offers the highest channel density and flexibility in the industry for a single-slot, 3U PXI plug-in board. 96 channels support TTL levels and an additional 32 I/O channels can be customized by installing one of Marvin Test Solutions' GX57xx series I/O modules. Alternatively, the remaining port can be configured to support 32 TTL channels.

  • 4-CH 14/16-Bit Up to 2 MS/s Simultaneous-Sampling Multi-Function DAQ PCI Express Cards

    DAQe-2000 Series - ADLINK Technology Inc.

    ADLINK DAQe-2000 series products are simultaneous-sampling multi-function PCI Express DAQ cards to meet a wide range of application requirements. The devices can simultaneously sample 4 AI channels with differential input configuration in order to achieve maximum noise elimination. They also provide 2-CH 12-bit analog outputs with waveform generation capability, which can be performed together with analog input functions. If more analog input or output channels are required, multiple cards can be synchronized through the SSI (system synchronization interface) bus. This makes the DAQe-2000 series ideal for the stimulus/response test.

  • Industrial Vibration Sensor

    IVS-500 - Polytec GmbH

    The new IVS-500 Industrial Vibration Sensor is the key to fast acoustic quality inspection, structure-borne noise analysis and reliable pass-fail decisions. This Laser sensor measures reliably, in demanding industrial environments, without contact and therefore without wear and on virtually all surfaces. Costs and yields are therefore optimized by reducing false rejects in the production and assembly process. The simple setup and ruggedized sensor design of the IVS-500 enable a smooth integration into production test systems. Complemented with the software tool QuickCheck, Polytec offers a comprehensive solution for reliable pass/fail analysis.

  • HIPOT Insulation Testers

    Laycock Systems

    Crown high voltage, transformer type hipot insulation testers are safe, easy to use for quick, positive determination of grounds, shorts, and broken wires in motors, transformers and other low voltage equipment or wiring systems. A turn of the selector switch gives a selection of seven voltages; 500, 1080, 1250, 1500, 1750, 2000 or 2500 volts calibrated to +/- 5% accuracy; NEMA recommendation for insulation test is twice normal voltage plus 1000 volts. Since this instrument has a capacity of 2500 volts, it readily accommodates all normal requirements.

Get Help